 General-purpose Relay
G2RS-(S)
Slim and Space-saving Power Plug-in Relay
* Lockable test button models now available. * Built-in mechanical operation indicator. * Provided with nameplate. * AC type is equipped with a coil-disconnection selfdiagnostic function (LED type). * High switching power (1-pole: 10 A). * Environment-friendly (Cd, Pb free). * Wide range of Sockets also available. * RoHS Compliant.
LR
Model Number Structure
Model Number Legend
G2R
1
2 3 4
5 6
7
(S)
5. Terminals S: Plug-in 6. Classification Blank:General-purpose N: LED indicator D: Diode ND: LED indicator and diode NI: LED indicator with test button NDI: LED indicator and diode with test button 7. Rated Coil Voltage
1. Relay Function Blank:General-purpose 2. Number of Poles 1: 1 pole 2: 2 poles 3. Contact Form Blank:SPDT 4. Contact Type Blank:Single
Ordering Information
List of Models
Classification Plug-in terminal General-purpose LED indicator LED indicator with test button Diode LED indicator and diode LED indicator and diode with test button DC Enclosure rating Unsealed Coil ratings AC/DC G2R-1-S G2R-1-SN G2R-1-SNI G2R-1-SD G2R-1-SND G2R-1-SNDI Contact form/Model SPDT DPDT G2R-2-S G2R-2-SN G2R-2-SNI G2R-2-SD G2R-2-SND G2R-2-SNDI
Note: When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table. New model Example: G2R-1-S DC12 (S) Rated coil voltage
General-purpose Relay
G2RS-(S)
245
Accessories (Order Separately)
Connecting Sockets
Applicable Relay model Track/surface-mounting Socket Screwless clamp terminal (See note.) 1 pole G2R-1-S(N)(D)(ND)(NI)(NDI) 2 poles G2R-2-S(N)(D)(ND)(NI)(NDI) P2RF-05-S + P2CM-S P2RF-08-S + P2CM-S Screw terminal P2RF-05-E P2RF-05 P2RF-08-E P2RF-08 Back-mounting Socket Terminals PCB terminals Solder terminals PCB terminals Solder terminals Model P2R-05P, P2R-057P P2R-05A P2R-08P, P2R-087P P2R-08A
Note: 1. Use of P2CM Clips are optional. However, use of the P2CM Clip & Release Lever is recommended to ensure stable mounting. 2. "-E" models are of finger-safe product construction. Round terminals cannot be used. Use Y-shaped terminals.
Accessories for Screwless Clamp Terminal Socket (Option)
Name Clip & Release Lever Nameplate Socket Bridge P2CM-S R99-11 Nameplate for MY P2RM-SR (for AC), P2RM-SB (for DC) Model
Mounting Tracks
Applicable Socket Mounting track and accessories Mounting track Description 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 PFP-M PFP-S P2R-P Model
End plate Spacer Mounting plate* Back-connecting Sockets
*Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
Coil Ratings
Rated voltage Rated current* Coil resistance* Coil inductance (H) (ref. value) Armature OFF 253 5,566 7,286 27,172 30,360 Coil resistance* 0.81 13.33 16.13 72.68 90.58 Armature ON 1.55 26.83 32.46 143.90 182.34 Must operate voltage Must release voltage Max. voltage Power consumption (approx.) Must operate voltage Must release voltage Max. voltage Power consumption (approx.) 50 Hz AC 24 V 110 V 120 V 230 V 240 V Rated voltage 43.5 mA 9.5 mA 8.6 mA 4.4 mA 3.7 mA 60 Hz 37.4 mA 8.2 mA 7.5 mA 3.8 mA 3.2 mA % of rated voltage 80% max. 30% min. 110% 0.9 VA at 60 Hz
Rated current*
Coil inductance (H) (ref. value) Armature OFF Armature ON 0.48 2.35 8.25 29.82
% of rated voltage 70% max. 15% min. 110% 0.53 W
DC
6V 12 V 24 V 48 V
87.0 mA 43.2 mA 21.6 mA 11.4 mA
69 278 1,113 4,220
0.25 0.98 3.60 15.2
* The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of 10%.
246
General-purpose Relay
G2RS-(S)
Contact Ratings
Number of poles Load Rated load Rated carry current Max. switching voltage Max. switching current Max. switching capacity Minimum permissible load Resistive load (cos = 1) 10 A at 250 VAC; 10 A at 30 VDC 10 A 440 VAC, 125 VDC 10 A 2,500 VA, 300 W 100 mA at 5 VDC 1,875 VA, 150 W 1 pole Inductive load (cos = 0.4; L/R = 7 ms) 7.5 A at 250 VAC; 5 A at 30 VDC Resistive load (cos = 1) 5 A at 250 VAC; 5 A at 30 VDC 5A 380 VAC, 125 VDC 5A 1,250 VA, 150 W 10 mA at 5 VDC 500 VA, 90 W 2 poles Inductive load (cos = 0.4; L/R = 7 ms) 2 A at 250 VAC; 3 A at 30 VDC
Note: P level: 60 = 0.1 x 10-6/operation
Characteristics
Item Contact resistance Operate (set) time Release (reset) time Max. operating frequency Insulation resistance Dielectric strength 100 m max. 15 ms max. AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.) Mechanical: Electrical: AC: 15 ms max.; DC: 10 ms max. (w/built-in diode: 20 ms max.) 1 pole 2 poles
18,000 operations/hr 1,800 operations/hr (under rated load)
1,000 M min. (at 500 VDC) 5,000 VAC, 50/60 Hz for 1 min between coil and contacts*; 5,000 VAC, 50/60 Hz for 1 min between coil and 3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity contacts*; 1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity same polarity Destruction: Malfunction: Destruction: Malfunction: Mechanical: Electrical: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 1,000 m/s2 200 m/s2 when energized; 100 m/s2 when not energized AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min. (at 18,000 operations/hr) 100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type) -40C to 70C (with no icing or condensation) 5% to 85%
Vibration resistance Shock resistance Service life
Ambient temperature Ambient humidity Weight
Operating: Operating: Approx. 21 g
Note: Values in the above table are the initial values. *4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is used.
Approved Standards
UL Recognized (File No. E41643) - - Ambient Temp. = 40C
Model Contact Coil ratings form
G2R-1-S SPDT
IEC/VDE (EN61810)
Contact form
1 pole
Contact ratings
Cycles
6 x 103
Coil ratings
6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC
Contact ratings
5 A, 440 VAC (cos = 1.0) 10 A, 250 VAC (cos = 1.0) 10 A, 30 VDC (0 ms) 5 A, 250 VAC (cos =1.0) 5 A, 30 VDC (0 ms)
Cycles
100 x 103
G2R-2-S DPDT
10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) 5 to 110 VDC TV-3 (NO contact only) 5 to 240 VAC 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only)
6 x 103
2 poles
100 x 103
CSA Certified (File No. LR31928)
Model Contact Coil ratings form
G2R-1-S SPDT
LR
Cycles
6 x 103
Contact ratings
Number of poles
1 pole
Coil ratings
5 to 110 VDC 5 to 240 VDC
Contact ratings
10 A, 250 VAC (general use) 7.5 A, 250 VAC (PF0.4) 10 A, 30 VDC (resistive) 5A, 30VDC (L/R=7ms) 5 A, 250 VAC (general use) 2 A, 250 VAC (PF0.4) 5 A, 30 VDC (resistive) 3A, 30VDC (L/R=7ms)
Cycles
G2R-2-S DPDT
10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) 5 to 110 VDC TV-3 (NO contact only) 5 to 240 VAC 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only)
100 x 103
6 x 103 2 poles 5 to 110 VDC 5 to 240 VDC
100 x 103
General-purpose Relay
G2RS-(S)
247
Engineering Data
Maximum Switching Capacity
Plug-in Relays
G2R-1-S
100
G2R-2-S
100
Switching current (A)
Switching current (A)
AC inductive load (cos = 0.4)
AC resistive load
10
DC resistive load DC inductive load (L/R = 7 ms)
10
AC inductive load (cos = 0.4)
AC resistive load
DC resistive load
1
1
DC inductive load (L/R = 7 ms)
0.1
1
10
100
1000
0.1
1
10
100
1000
Switching voltage (V)
Switching voltage (V)
Electrical Service Life
Plug-in Relays
G2R-1-S
Service LIfe (x103 operations) Service Life (x103 operations)
5,000
G2R-2-S
10,000 5,000
1,000 500
250-VAC/30-VDC resistive load 250-VAC inductive load (cos = 0.4)
1,000 500
30-VDC inductive load (L/R = 7ms) 250-VAC/30-VDC resistive load
100 50
30-VDC inductive load (L/R = 7ms)
100
250-VAC 50 inductive load (cos = 0.4)
Switching current (A)
Switching current (A)
Ambient Temperature vs. Maximum Coil Voltage
Maximum voltage (%)
DC coil
AC coil
Note: The maximum voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient temperature (C)
248
General-purpose Relay
G2RS-(S)
Dimensions
Unit: mm (inch)
Relays with Plug-in Terminals
SPDT Relays
G2R-1-S, G2R-1-SN, G2R-1-SNI G2R-1-SD, G2R-1-SND, G2R-1-SNDI
Terminal Arrangement/Internal Connections (Bottom View)
G2R-1-S
1
G2R-1-SD (DC)
29 (1.14) max.
13 max. (0.51) 35.5 max. (1.40)
1
5
2
4
3
5
2
4
3
20 (0.79)
G2R-1-SN, G2R-1-SNI (AC)
G2R-1-SN, G2R-1-SNI (DC)
1
DC 24 V
1
5 (0.20) 0.5 (0.02) 4.75 (0.19) 1(0.04)
5
2
4
3
5
2
4
3
7.5 (0.29)
G2R-1-SND, G2R-1-SNDI (DC)
5.2 (0.20) 5.2 (0.20) 17.5 (0.69)
1
5
2
4
3
DPDT Relays
G2R-2-S, G2R-2-SN, G2R-2-SNI G2R-2-SD, G2R-2-SND, G2R-2-SNDI
Terminal Arrangement/Internal Connections (Bottom View)
G2R-2-S
1 2 3 4
G2R-2-SD (DC)
1 2 3 4
29 max. (1.14)
13 max. (0.51)
8
35.5 max. (1.40) 20 (0.79)
7
6
5
8
7
6
5
G2R-2-SN, G2R-2-SNI (AC)
1 2 3 4
G2R-2-SN, G2R-2-SNI (DC)
1 2 3 4
0.5 (0.02) 7.4 (0.29)
2.5 (0.10)
2.4 (0.09) 8.9 (0.35)
6.2 (0.29)
8
7
6
5
8
7
6
5
G2R-2-SND, G2R-2-SNDI (DC)
1
5 (0.02)
5 (0.02) 19.4 (0.76)
2
3
4
8
7
6
5
General-purpose Relay
G2RS-(S)
249
Track/Surface Mounting Sockets
P2RF-05-S
38.2 max. (1.50) 36.5 max. (1.44) Terminal Arrangement (Top View)
11 14 12
32.6 (1.28) 27.6 (1.09) 22.6 (0.89) 24.5 (0.96)
92.0 max. (3.62) Option (with ejector and label attached)
35.4 (1.39)
A1 A2
Standard model
28.5 (1.12) 18.0 max. (0.71) 32.6 (1.28)
5.3 typical (0.21)
P2RF-08-S
38.2 max. (1.50) 36.5 max.(1.44)
Terminal Arrangement (Top View)
21 11 24 14 32.6 (1.28) 27.6 (1.09) 22.6 (0.89) 3.4 (0.13) typical 22 12
24.5 (0.96)
92.0 max. (3.62)
35.4 (1.39)
A1 A2
Standard model
Option (with ejector and label attached)
28.6 (1.12) 18.0 max. (0.71) 32.6 (1.28)
5.3 typical (0.21)
Accessories for P2RF-@-S
Socket Bridge Clip and Release Lever
16.8 (0.66)
40.35 (1.59)
Note: The color of insulating coating indicates power type.
36 (1.42)
Model P2RM-SR P2RM-SB AC DC
Power Red Blue
Color
250
General-purpose Relay
G2RS-(S)
P2RF-05-E
Five, M3.5x7 2 (0.08) 48 max. (1.89)
Terminal Arrangement (Top View)
(11)
2
Mounting Holes (for Surface Mounting)
3.2 (0.13) dia. hole 39.50.1 (1.55 0.004)
4
85.5 max. (3.37)
3.5 (0.14) dia. hole
39.5 (1.55) 35.5 (1.40)
(14)
3
(12)
5
5 (0.20)
16.0 max. (0.63)
61 max. (2.40)
11.5 (0.45)
(A1) (A2)
1
M3 or 3.5 (0.14) dia.
Note: Pin numbers in parentheses apply to DIN standard. Terminal Arrangement (Top View)
(21) (22) (24)
6 7 5 3 2 4
P2RF-08-E
2 (0.08) 1.5 (0.06) Eight, M3x8 48.0 max. (1.89) 2 (0.08) 3 (0.12) 39.5 (1.55)
Mounting Holes (for Surface Mounting)
(11) (12) (14)
3.2 (0.13) dia. hole 39.50.1 (1.550.004)
85.5 max (3.37)
35.5 (1.40)
3.5 (0.14) dia. hole 11.5 (0.45) 5 (0.20) 16.0 (0.63) max. 61.0 max. (2.40)
8
(A1)
1
(A2)
M3 or 3.5 (0.14) dia. hole
P2RF-05
7(0.28) Five, M3.5 x 8
2 (0.08) 4 (0.16) dia. holes 35.5 (1.40)
Terminal Arrangement (Top View)
Mounting Holes (for Surface Mounting)
4.2 (0.16) dia. hole 300.05 (1.180.002)
71.5 max. (2.81)
4 (0.16) 19.5 max. (0.77)
19.5 (0.77) 30 max.(1.18) 54 max. (2.12)
M3 or 3.2 (0.13) dia. hole
P2RF-08
7 (0.28) Eight, M3.5 x 8 4 (0.16) dia. holes 71.5 max. (2.89) 35.5 (1.40) 300.05 (1.180.002) 2 (0.08)
Terminal Arrangement (Top View)
Mounting Holes (for Surface Mounting)
4.2 (0.16) dia. hole
4 (0.16)
19.5 max. (0.77)
19.5 (0.77) 30 max.(1.18) 54 max. (2.12)
M3 or 3.2 (0.13) dia. hole
General-purpose Relay
G2RS-(S)
251
Mounting Height of Relay with Track/Surface Mounting Sockets
P2RF-@ P2RF-@-E
66.5 (2.62)
62.0 (2.44)
67.0 (2.64)
70.5 (2.77)
P2RF-@-S
72.0 (2.83) 65.0 (2.56) 28.6 (1.12)
5.30 (0.21) typical
Back-connecting Sockets
P2R-05P (1-pole)
4 (0.16) 1(0.04) 6 (0.24) 4.5 (0.18) 15 (0.59) 1.2 (0.05) 4 (0.16)
3.5 (0.14)
7 (0.27)
14.5 max. (0.57)
Terminal Arrangement (Bottom View)
Mounting Holes
Tolerance: 0.1 4 (0.14) Five, 1.6 (0.06) dia. holes
35.5 max. (1.40)
6 (0.24) 4.5 (0.18) 15 (0.59)
1.5 (0.06) 7 (0.27) 4 (0.16)
4 (0.16) 5 (0.20) typical 7 (2.27)
P2R-08P (2-pole)
0.3 4 (0.16) (0.01) 5 (0.20) 5 (0.20) 20 (0.79) 2.8 (0.11) 1.5 (0.06) 7.5 (0.29) Terminal plate thickness: 0.3 (0.01) 1 (0.04)
36.5 max. (1.44) 14.5 max. (0.57)
7 (0.27)
Terminal Arrangement (Bottom View)
Mounting Holes
7.5 (0.29) Eight, 1.3 (0.05) dia. holes
35.5 max. (1.40)
5 (0.20) 5 (0.20) 20 (0.79)
4.3 (0.17) typical
36.5 max. (1.44)
252
General-purpose Relay
G2RS-(S)
P2R-05A (1-pole)
5 (0.20) 0.3 (0.01)
7 (0.28) 1.2 (0.05)
14.5 max. (0.57)
6.7 (0.26) 3.8 (0.15) 16.7 5 (0.20) (0.66)
Terminal Arrangement (Bottom View)
35.5 max. (1.40)
Panel Cutout
Five, 3 x 1.8-dia. holes (0.12 x 0.07) 6 (0.24) 13.60.1 (0.540.004)
Terminal plate thickness: 0.3
36.5 max. (1.44)
P2R-08A (2-pole)
7 (0.28) 0.3 (0.01) 5 (0.20) 5 (0.20) 20 (0.79) 2.8(0.11) 1.5 (0.06) 2.6 (0.10)
7 (0.28) 1.2 (0.05)
14.5 max. (0.57)
30.50.2 (1.200.008)
35.5 max. (1.40)
Recommended thickness of the panel is 1.6 to 2.0 mm
Eight, 3 x 1.2 (0.12 x 0.05)dia. holes
7.5 (0.30) Terminal plate thickness: 0.3 36.5 max. (1.44)
P2R-057P
14 max. (0.55) 8.7 (0.34)
16.4 (0.65) 1(0.04) 10.4 (0.41)
0.7 (0.03)
Terminal Arrangement (Bottom View)
Mounting Holes
40.1 (0.160.004) Five, 1.6 (0.06) dia. holes 60.1(0.240.004)
4.50.1 150.1(0.590.004) (0.180.004)
37 max. 29.6 (1.46) (1.17)
8.7 (0.34)
7.4 (0.29)
40.1 (0.160.004) 5 (0.20) 70.1(0.270.004)
P2R-087P
14 max. (0.55) 7.5 (0.30)
41 max. (1.61)
16.4(0.65) 1 (0.04)
10.4 (0.41)
Terminal Arrangement (Bottom View)
Mounting Holes
7.5 (0.30) Eight, 1.3 (0.05) dia. holes 5 (0.20) 5 (0.20) 20 (0.79)
37 max. (1.46) 29.1 (1.15)
8.9 (0.35)
7.4 (0.29) 8.1(0.32) typical
41 max. (1.61)
General-purpose Relay
G2RS-(S)
253
Mounting Height of Relay with Back-connecting Sockets
G2R-@P
G2R Relay 44.5 (1.75) 38.0 (1.50)
G2R-@A
G2R Relay P2R-_A Socket
G2R-@7P
47.5 (1.87)
P2R-_P Socket
Mounting Tracks
PFP-100N, PFP-50N PFP-100N2
4.5 (0.18)
7.30.15 (0.290.006) 4.5 (0.18)
16 (0.63)
350.3 15 (0.59) 25 10 25 (0.98)
1,000 (39.37) or 500 (19.68)
270.15 1
15 (0.59)
24 27 350.3 (0.94) (1.380.01) (1.06)
29.2 (1.15) 1.5 (0.06)
25
25
10 (0.39)
15(0.59) or 5 (0.20)
25 10
25 (0.98)
25
25 15
10 (0.39)
1 (0.04)
1,000 (39.37)
It is recommended to use a panel 1.6 to 2.0 mm thick.
End Plate
PFP-M
10 (0.39) 6.2 (0.24) 1.8 (0.07)
Spacer
16 (0.63)
PFP-S
5 (0.20)
12 (0.47)
50 (1.97)
1 (0.04)
35.5 35.3 1.8 (1.40) (1.39) (0.07)
44.3 (1.74)
34.8 (1.37)
11.5 (0.45) 10 (0.39) M4 x 8 pan head screw
1.3 (0.05) 4.8 (0.19)
16.5 (0.65)
Precautions
!CAUTION
Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely.
Precautions for P2RF-@-S Connection
* Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. * Do not insert the screwdriver at an angle. Doing so may break the side of the socket and result in a short-circuit.
!CAUTION
Check that the test button is released before turning ON relay circuits.
!CAUTION
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
!CAUTION
Use an insulated tool when you operate the test button.
254
General-purpose Relay
G2RS-(S)
Omron Electronic Components, LLC
Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer of Products, including any end user in section III through VI (d) Products: Products and/or services of Seller (e) Including: Including without limitation 2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 3. Distributor: Any distributor shall inform its customer of the contents after and including section III of these Terms. II. SALES 1. Prices; Payment: All prices stated are current, subject to change without notice by Seller. Buyer agrees to pay the price in effect at the time the purchase order is accepted by Seller. Payments for Products received are due net 30 days unless otherwise stated in the invoice. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. 2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past due amounts owing to Seller. 3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 4. Orders: Seller will accept no order less than 200 U.S. dollars net billing. 5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer shall make remittance to Seller at the then current exchange rate most favorable to Seller; provided that if remittance is not made when due, Buyer will convert the amount to U.S. dollars at the then current exchange rate most favorable to Seller available during the period between the due date and the date remittance is actually made. 6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining any government approvals regarding the importation or sale of the Products. 7. Taxes: All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Seller or required to be collected directly or indirectly by Seller for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Seller. 8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller, Seller reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Seller may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Seller fully against all costs or expenses arising in connection therewith. 10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller: (a) All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Seller), at which point title to and all risk of loss of the Products shall pass from Seller to Buyer, provided that Seller shall retain a security interest in the Products until the full purchase price is paid by Buyer; (b) Delivery and shipping dates are estimates only; and (c) Seller will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products occurring before delivery to the carrier or any claim related to pricing or other charges must be presented in detail in writing to Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability: IT IS THE BUYER'S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER'S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT. Buyer acknowledges that it alone has determined that the Products will meet their requirements of the intended use in all cases. Buyer must know and observe all prohibitions of use applicable to the Product/s. 2. Use with Attention: The followings are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible use of any Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference.
(b) Use in consumer Products or any use in significant quantities. (c) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) Systems, machines, and equipment that could present a risk to life or property. 3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY SELLER. 5. Programmable Products: Seller shall not be responsible for the Buyer's programming of a programmable Product. IV. WARRANTY AND LIMITATION 1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Seller (or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. 2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an amount equal to the purchase price of the Product; provided that there shall be no liability for Seller or its affiliates unless Seller's analysis confirms that the Products were correctly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Seller before shipment. 3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED. 4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. V. INFORMATION; ETC. 1. Intellectual Property: The intellectual property embodied in the Products is the exclusive property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way without the written permission of Seller. Buyer (at its own expense) shall indemnify and hold harmless Seller and defend or settle any action brought against Seller to the extent that it is based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Seller. All information and materials supplied by Seller to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 3. Performance Data: Performance data is provided as a guide in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. 4. Change In Specifications: Product specifications and descriptions may be changed at any time based on improvements or other reasons. It is Seller's practice to change part numbers when published ratings or features are changed, or when significant engineering changes are made. However, some specifications of the Product may be changed without any notice. 5. Errors And Omissions: The information on Seller's website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses regarding (a) export of the Products or information provided by Seller; (b) sale of Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information. VI. MISCELLANEOUS 1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing between Buyer and Seller shall operate as a waiver of rights by Seller. 2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent. 3. Law: These Terms are governed by Illinois law (without regard to conflict of laws). Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any dispute hereunder. 4. Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision.
General-purpose Relay
G2RS-(S)
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) Use in consumer products or any use in significant quantities. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Seller representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 6. RoHS Compliance. Where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information.
Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website at http://www.components.omron.com - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ELECTRONIC COMPONENTS LLC
55 E. Commerce Drive, Suite B Schaumburg, IL 60173
OMRON ON-LINE
Global - http://www.omron.com USA - http://www.components.omron.com
847-882-2288
Cat. No. X301-E-1a 06/09 Specifications subject to change without notice Printed in USA
General-purpose Relay
G2RS-(S)


▲Up To Search▲   

 
Price & Availability of G2R-1-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X